e2xl15f-loa-phong-thanh-15w-pa-loudspeakers-15w.png
Csfm Ul Iecex-approval Atex-approval Culs-approval Ce-approval
1-32-030

E2xL15F PA Loudspeakers 15W

The hazardous area E2xL15F PA loudspeaker is UL/cULs approved for Class I Div 2 and Class II Div 2 as well as IECEx and ATEX certified for Zone 2 and 22 applications.

The E2xL15F is available with either a 70V or 100V line transformer or as a low impedance loudspeaker. 
The E2x range features enclosures manufactured from lightweight, corrosion proof PPS and high impact, fire retardant ABS re-entrant flare horns; both of which are suitable for the harshest of environments.

Specification

 
SPL: 108dB +/-3dB @ 1w @ 1m (Pink noise)
118dB +/-3dB @ 15w @ 1m (Rated)
Rated power: 15 Watts RMS
70v line tappings: 15w / 7.5w / 3w / 1w
-(z=336.67 Ohms / 653.33 Ohms / 1.6k Ohms / 4.9k Ohms)
100v line tappings: 15w / 7.5w / 3w / 1w
-(z=666.87 Ohms / 1.34k Ohms / 3.34k Ohms / 10k Ohms)
Low impedence: 8 Ohm (I/P: 10.95V)
-or 16 Ohm (I/P: 15.49V)
Dispersion: 120° @ 1kHz & 32° @ 4kHz
Frequency range: 400Hz to 8000 Hz
DC Line monitoring: 2.2µF Capacitor
-(Transformer version)
Ingress protection: IP rating per EN60079-0:IP64
IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/13
Enclosure material: UL94V0 PPS & ABS
Cable entries: Dual M20x1.5 or 1/2"NPT
Terminals: 0.5 - 2.5mm² (20-14 AWG)
Operating temp: -20 to +55°C [-4° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: Low impedance: 2.5kg/5.5Ibs
-Transformer: 3.00kg/6.6Ibs
*SPL data +/-3dB(A). Measured at optimum voltage.

Part Codes

Part Code: Ident.: Description:
Product type: E2xL15
Horn type: F Flare Horn
Type: V100
V070
R008
R016
100V Line
70V Line
8 Ohm Low impedance
16 Ohm Low impedance
Cable entries: A
B
C
M20x1.5 & ½” NPT
M20x1.5 & M20x1.5
½” NPT & ½” NPT
Stopping plug material: N Nylon
Bracket: 1
2
304 (A2) Stainless Steel
316 (A4) Stainless Steel
Approvals: A1 UL, cULs, IECEx & ATEX
Enclosure: B Black
e.g: E2xL15FV100AN1A1B E2xL15 PA Loudspeaker with flare horn.
100V line transformer with one M20 cable entry and one 1/2"NPT entry.
Approved to IECEx, ATEX & UL.
Black enclosure.

Coding

  • IECEx / ATEX:
    II 3G Ex nA IIC T4 Gc Ta -20°C to +55°C
    II 3D Ex tc IIIC T85°C Dc Ta -20°C to +55°C
  • NEC Class / Zone ratings US:
    Class I Zone 2 AEx nA IIC T4 Gc Ta -20°C to +55°C
    Zone 22 AEx tc IIIC T85°C Dc Ta -20°C to +55°C
  • CEC Class / Zone ratings Canada
    Ex nA IIC T2 Gc Ta -20°C to +55°C
    Ex tc IIIC 85°C Dc Ta -20°C to +55°C
  • NEC & CEC Class / Division Ratings for US / Canada
    Class I, Div 2, ABCD T3C Ta -20°C to +55°C
    Class I, Div 2, ABCD T4 Ta -20°C to +40°C
    Class II, Div 2, FG T6 Ta -20°C to +55°C
    Class II, Div 2, FG T6 Ta -20°C to +55°C

E2xL15F PA Loudspeakers 15W

  • Very large termination area.
  • Ratchet adjustable stainless steel ‘U’ bracket.
  • Transformer type fitted with thermal fuse
  • Complies with BS5839 part 8 *

Approvals

  • ATEX certificate: DEMKO 06 ATEX 0421554X

  • IECEx certficate: IECEx ULD 14.0012X

  • UL/cUL File ref: E230764

  • CSFM listing: 7136-2279:0505

1-32-030e2xl15_cat