Loa báo động IS-A105N Alarm Sounder, vật liệu UL94V0
Xuất sứ: UK
Nhà cung cấp: STC Vietnam
Hãng sản xuất: E2S Warning Signals VietNam
Ứng dụng sản phẩm: Dầu khí_Công Nghiệp_Hóa Dầu_Hàng Hải
1-12-020
IS-A105N Alarm Sounder
The IS-A105N is a high output, 105dB(A) alarm sounder. Approvals include ATEX, IECEx and GOST-R for Zone 0 applications and FM approval for Class I Division 1 and Class I Zone 0 applications.
The IS-A105N is suitable for all intrinsically safe signalling applications including fire, security and process control.
Specification
| Nominal output: | 105dB(A) @ 1m +/- 3dB - Tone 2*[96dB(A) @ 10ft/3m] | |
| No. of tones: | 49 (UKOOA/PFEER compliant) | |
| No. of stages: | 3 | |
| Volume control: | Max. 105dB(A); Min. 96dB(A) - Tone 2 |
|
| Effective range: | 60m/197ft @ 1KHz | |
| Voltage: | 16-28vdc via Zener barrier or galvanic isolator | |
| Current: | 25mA typical when powered from 24v supply via 28v 300 Ohm Zener barrier |
|
| Ingress protection: | IP66 | |
| Rating: | Continuous | |
| Housing material: | UL94V0 & 5VA FR ABS | |
| Housing colour: | RAL3000 Red, RAL7038 Grey and White | |
| Fixings: | Stainless Steel | |
| Cable entries: | 2 x M20 clearance gland knockouts. Custom configurations also available. |
|
| Terminals: | 0.5 to 2.5mm² | |
| Operating temp: | -40° to +60°C [-40 to +140°F] | |
| Storage temp: | -40° to +70°C [-40 to +158°F] | |
| Relative humidity: | 90% at 20°C [68°F] | |
| Weight : | 0.75kg/1.65Ibs | |
Part Codes
| IS-A105N-[x] | |||
| ATEX / IECEx / FM | |||
| II 1G Ex ia IIC T4 Ga (-40ºC <=Ta<= +60°C) | |||
| IS Class I, Zone 0, AEx ia IIC T4 Ta = +60°C | |||
| IS Class l, Division 1, Groups A, B, C, D T4 | |||
| GOST-R | |||
| 0ExiaIICT4 IP66 -40° to +60°C | |||
| [x] : Housing colour: | R: Red | G: Grey | W: White |
| May be powered from any certified Zener barrier or galvanic isolator whose output parameters do not exceed : |
|||
| Uo : 28VDC | Io : 93mA | Po : 660mW | |
Tone Table
| Stage 1 | WAV file | Frequency Description. | Stg 2 | Stg 3 |
|---|---|---|---|---|
| T 1 | ↓ |
340 Hz Continuous | T 2 | T 5 |
| T 2 | ↓ |
800/1000Hz @ 0.25 sec Alternating | T 17 | T 5 |
| T 3 | ↓ |
500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop | T 2 | T 5 |
| T 4 | ↓ |
800/1000Hz @ 1Hz Sweeping | T 6 | T 5 |
| T 5 | ↓ |
2400Hz Continuous | T 3 | T 20 |
| T 6 | ↓ |
2400/2900Hz @ 7Hz Sweeping | T 7 | T 5 |
| T 7 | ↓ |
2400/2900Hz @ 1Hz Sweeping | T 10 | T 5 |
| T 8 | ↓ |
500/1200/500Hz @ 0.3Hz Sweeping | T 2 | T 5 |
| T 9 | ↓ |
1200/500Hz @ 1Hz - DIN / PFEER P.T.A.P. | T 15 | T 2 |
| T 10 | ↓ |
2400/2900Hz @ 2Hz Alternating | T 7 | T 5 |
| T 11 | ↓ |
1000Hz @ 1Hz Intermittent | T 2 | T 5 |
| T 12 | ↓ |
800/1000Hz @ 0.875Hz Alternating | T 4 | T 5 |
| T 13 | ↓ |
2400Hz @ 1Hz Intermittent | T 15 | T 5 |
| T 14 | ↓ |
800Hz 0.25sec on, 1 sec off Intermittent | T 4 | T 5 |
| T 15 | ↓ |
800Hz Continuous | T 2 | T 5 |
| T 16 | ↓ |
660Hz 150mS on, 150mS off Intermittent | T 18 | T 5 |
| T 17 | ↓ |
544Hz (100mS)/440Hz (400mS) - NF S 32-001 | T 2 | T 27 |
| T 18 | ↓ |
660Hz 1.8sec on, 1.8sec off Intermittent | T 2 | T 5 |
| T 19 | ↓ |
1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s -NFC48-265 | T 2 | T 5 |
| T 20 | ↓ |
660Hz Continuous | T 2 | T 5 |
| T 21 | ↓ |
554Hz/440Hz @ 1Hz Alternating | T 2 | T 5 |
| T 22 | ↓ |
544Hz @ 0.875 sec. Intermittent | T 2 | T 5 |
| T 23 | ↓ |
800Hz @ 2Hz Intermittent | T 6 | T 5 |
| T 24 | ↓ |
800/1000Hz @ 50Hz Sweeping | T 29 | T 5 |
| T 25 | ↓ |
2400/2900Hz @ 50Hz Sweeping | T 29 | T 5 |
| T 26 | ↓ |
Bell | T 2 | T 15 |
| T 27 | ↓ |
554Hz Continuous | T 26 | T 5 |
| T 28 | ↓ |
440Hz Continuous | T 2 | T 5 |
| T 29 | ↓ |
800/1000Hz @ 7Hz Sweeping | T 7 | T 5 |
| T 30 | ↓ |
300Hz Continuous | T 2 | T 5 |
| T 31 | ↓ |
660/1200Hz @ 1Hz Sweeping | T 26 | T 5 |
| T 32 | ↓ |
Two T chime. | T 26 | T 15 |
| T 33 | ↓ |
745Hz @ 1Hz Intermittent | T 2 | T 5 |
| T 34 | ↓ |
1000 & 2000Hz @ 0.5 sec Alternating - Singapore | T 38 | T 45 |
| T 35 | ↓ |
420Hz @ 0.625 sec Australian Alert | T 36 | T 5 |
| T 36 | ↓ |
500-1200Hz 3.75sec /0.25sec. Australian Evac. | T 35 | T 5 |
| T 37 | ↓ |
1000Hz Continuous - PFEER Toxic Gas | T 9 | T 45 |
| T 38 | ↓ |
2000Hz Continuous | T 34 | T 45 |
| T 39 | ↓ |
800Hz 0.25sec on, 1 sec off Intermittent | T 23 | T 17 |
| T 40 | ↓ |
544Hz (100mS)/440Hz (400mS) - NF S 32-001 | T 31 | T 27 |
| T 41 | ↓ |
Motor Siren - slow rise to 1200 Hz | T 2 | T 5 |
| T 42 | ↓ |
Motor Siren - slow rise to 800 Hz | T 2 | T 5 |
| T 43 | ↓ |
1200 Hz Continuous | T 2 | T 5 |
| T 44 | ↓ |
Motor Siren - slow rise to 2400 Hz | T 2 | T 5 |
| T 45 | ↓ |
1KHz 1s on, 1s off Intermittent - PFEER Gen. Alarm | T 38 | T 34 |
| T 46 | ↓ |
1200/500Hz @ 1Hz - DIN / PFEER P.T.A.P. | T 47 | T 37 |
| T 47 | ↓ |
1KHz 1s on, 1s off Intermittent - PFEER Gen. Alarm | T 46 | T 37 |
| T 48 | ↓ |
420Hz @ 0.625 sec Australian Alert | T 49 | T 5 |
| T 49 | ↓ |
500-1200Hz 3.75sec /0.25sec. Australian Evac. | T 26 | T 37 |
| Country specific or custom tone configurations and alarm frequencies are available upon request. | ||||