d1xc2x05f-loa-bao-va-den-xenon-nhap-nhay-5-joule-alarm-horn-xenon-strobe.png
Ul_badge_-_certified Ul Csfm Culs-approval Ce-approval
1-23-070

D1xC2X05F Alarm Horn & Xenon Strobe

125dB(A) horn & 5 Joule Xenon. The D1xC2X05F is a high output alarm horn sounder with re-entrant flare horn combined with a 500,000cd Xenon strobe beacon. The robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosure ensures the D1xC2X05F is suitable for all Class I & II Division 1, Zone 1 & 20 explosion proof signaling applications. The Class I DC version is approved for public mode fire alarm use (alarm horn) and private mode fire alarm use (strobe beacon).

The alarm horn & Xenon strobe allow simultaneous or independent operation. Featuring 64 first stage/channel alarm sounds, the alarm tone frequencies for the first 2 stages are independently selectable. Each of the 4 stage/channels can be remotely triggered e.g. via an external relay.

Specification

 
Alarm Horn:
Maximum output: 125dB(A) @ 1 metre [116dB(A) @ 10ft/3m]
Nominal output: 120dB(A) @ 1m +/- 3dB - Tone 35 [112dB(A) @ 10ft/3m]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Adjustable -12dB(A)
Effective range: 200m/656ft @ 1KHz
Supply Voltages: 24Vdc; 115Vac; 230Vac
Stage switching: DC units: negative or positive
AC units: common supply line
Strobe Beacon:
Energy: 5 Joules (5Ws)
Flash rates: Option 1: 1Hz (60 fpm)
Option 2: 1.5Hz (90 fpm)
Option 3: Double Strike
Peak Candela: 500,000 cd - calculated from energy (J)
Effective Intensity: 250 cd - calculated from energy (J)
Peak Candela: 46,976 cd* - measured ref. to I.E.S.
Effective Intensity: 143 cd* - measured ref. to I.E.S.
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life : Emissions are reduced to 70% after 5 million flashes
General:
Ingress protection: EN60529: IP66
UL50E / NEMA250: 4 / 4X / 3R / 13
Enclosure material: Marine grade aluminium LM6- copper free
Chromated & powder coated - corrosion proof
Colour: Red (RAL3000), Grey (RAL7038)
Cable entries: 1 x 1/2"NPT & 2 x M20 x 1.5mm
1 x 1/2"NPT & 2 x 1/2"NPT
1 x 1/2"NPT & 2 x 3/4"NPT
Terminals: 0.5 - 2.5mm² (20-14 AWG)
Grounding stud: M5
Operating temp: 24Vdc & 115Vac: -40° to +70°C [-40° to +158°F]
230Vac: -40° to +55°C [-40° to +131°F]
Storage temp: -50° to +70°C [-58° to +158°F]
Relative humidity: 95% - Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight: 5.4kg/12.0lbs

Current Consumption

Voltage: Range: Alarm Horn Xenon Strobe Combined
24V dc 20-28Vdc 923mA 322mA 1245mA
115V ac 110-120Vac
50/60Hz
267mA 129mA 396mA
230V ac 220-240Vac
50/60Hz
159mA 79mA 238mA

Part Codes

Version: Part code:
Product type: D1xC2X05
Horn type: F Flare re-entrant horn
Voltage: DC024
AC115
AC230
20-28V dc
110-120V ac
220-240V ac
Cable Entry Type:[e] A
B
C
1 x 1/2"NPT & 2 x M20 x 1.5mm
1 x 1/2"NPT & 2 x 1/2"NPT
1 x 1/2"NPT & 2 x 3/4"NPT
Adaptor/Stopping
plug material: [m]
B
N
S
Brass
Nickel Plated
Stainless Steel
Bracket/Guard material: [s] 1
2
3
4
A2 304 Stainless Steel
A4 316 Stainless Steel
A2 304 St/St with Equip. Tag
A4 316 St/St with Equip. Tag (304)
Product version: [v] A1
D1
Gas environments Class I/Zone1
Dust environments Class II/Zone 20
Enclosure colour: [x] G
R
Grey RAL7038
Red RAL3000
Lens colour: [y] A, B, C, G
M, R, Y
Amber, Blue, Clear, Green
Magenta, Red, Yellow
Example: D1xC2X05FAC230 [e][m][s][v][x][y]
D1xC2X05FAC230AB1A1R/A
Ratings:
A1: Gas version
NEC / CEC: Class I Div 1 ABCD T5/T6 Ta -40°C to +55/+50°C
Class I Div 2 ABCD T5/T6 Ta -40°C to +55/+50°C
Class I Zone 1, 2 IIC T5/T6 Ta -40°C to +55/+50°C
D1: Dust version
NEC / CEC: Class II Div 1 FG T4/T4A Ta -40°C to +55/+40°C
Class II Div 2 FG T4/T4A Ta -40°C to +55/+40°C
Class III Div 1&2
Zone 20, 21, 22 IIIB T4/T4A Ta -40°C to +55/+40°C

Coding

  • A1: Gas version 
    NEC / CEC: 
    Class I Div 1 ABCD T5/T6 Ta -40°C to +55/+50°C 
    Class I Div 2 ABCD T5/T6 Ta -40°C to +55/+50°C 
    Class I Zone 1, 2 IIC T5/T6 Ta -40°C to +55/+50°C
  • D1: Dust version 
    NEC / CEC: 
    Class II Div 1 FG T4/T4A Ta -40°C to +55/+40°C 
    Class II Div 2 FG T4/T4A Ta -40°C to +55/+40°C 
    Class III Div 1 & 2 
    Zone 20, 21, 22 IIIB T4/T4A Ta -40°C to +55/+40°C
  • Protection concept: Ex d / AEx d

Effective Candela lens colour factor

 
Amber Blue Clear Green Red Yellow
0.70 0.24 1.00 0.25 0.23 0.93

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T1   1000 Continuous PFEER Toxic Gas Any T2 T44
T2   1200/500 @ 1Hz Sweeping DIN/PFEER P.T.A.P. Any T3 T44
T3   1000 @ 0.5Hz (1s on, 1s off) Intermittent PFEER Gen. Alarm Any T2 T44
T4   1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s NF C 48-265 Any T24 T1
T5   544(100mS)/440 (400mS) NF S 32-001 Any T19 T1
T6   1500/500 - (0.5s on , 0.5s off) x3 + 1s gap AS4428 Any T44 T1
T7   500-1500Hz Sweeping 2 sec on 1 sec off AS4428 Any T44 T1
T8   500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) NEN 2575 Any T24 T35
T9   1000 (1s on, 1s off)x7 + (7s on, 1s off) IMO Code 1a Any T34 T1
T10   1000 (1s on, 1s off)x7 + (7s on, 1s off) IMO Code 1a Any T34 T1
T11   420(0.5s on, 0.5s off)x3 + 1s gap ISO 8201 Temporal Any T1 T8
T12   1000(0.5s on, 0.5s off)x3 + 1s gap ISO 8201 Temporal Any T1 T8
T13   422/775 (0.85 on, 0.5 off) x3 + 1s gap NFPA Temporal Any T1 T8
T14   1000/2000 @ 1Hz - Singapore Any T3 T35
T15   300 Continuous Any T24 T35
T16   440 Continuous Any T24 T35
T17   470 Continuous Any T24 T35
T18   500 Continuous IMO code 2 (Low) Any T24 T35
T19   554 Continuous Any T24 T35
T20   660 Continuous Any T24 T35
T21   800 Continuous IMO code 2 (High) Any T24 T35
T22   1200 Continuous Any T24 T35
T23   2000 Continuous Any T3 T35
T24   2400 Continuous Any T20 T35
T25   440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent Any T44 T8
T26   470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent Any T44 T8
T27   470 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T44 T8
T28   544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent Any T24 T8
T29   655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent Any T44 T8
T30   660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent Any T24 T8
T31   660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent Any T24 T8
T32   745 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T33   800 (0.25s on, 1.00s off) Intermittent Any T24 T8
T34   800 @ 2Hz (0.25s on, 0.25s off) IMO code 3.a (High) Any T24 T8
T35   1000 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T36   2400 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T37   2900 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T24 T8
T38   363/518 @ 1Hz (0.50s/0.50s) Alternating Any T8 T19
T39   450/500 @ 2Hz (0.25s/0.25s) Alternating Any T8 T19
T40   554/440 @ 1Hz (0.50s/0.50s) Alternating Any T24 T19
T41   554/440 @ 0.65Hz (0.76s/0.76s) Alternating Any T8 T19
T42   561/760 @ 0.83Hz (0.60s/0.60s) Alternating Any T8 T19
T43   780/600 @ 0.96Hz (0.52s/0.52s) Alternating Any T8 T19
T44   800/1000 @ 2Hz (0.25s/0.25s) Alternating Any T24 T19
T45   970/800 @ 2Hz (0.25s/0.25s) Alternating Any T8 T19
T46   800/1000 @ 0.875Hz (0.57s/0.57s) Alternating Any T24 T19
T47   2400/2900 @ 2Hz (0.25s/0.25s) Alternating Any T24 T19
T48   500/1200 @ 0.3Hz (1.67s/1.67s) Sweeping Any T24 T12
T49   560/1055 @ 0.18Hz (2.73s/2.73s) Sweeping Any T24 T12
T50   560/1055 @ 3.3Hz (0.15s/0.15s) Sweeping Any T24 T12
T51   600/1250 @ 0.125Hz (4s/4s) Sweeping Any T24 T12
T52   660/1200 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T53   800/1000 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T54   800/1000 @ 7Hz (0.07s/0.07s) Sweeping Any T24 T12
T55   800/1000 @ 50Hz (0.01s/0.01s) Sweeping Any T24 T12
T56   2400/2900 @ 7Hz (0.07s/0.07s) Sweeping Any T24 T12
T57   2400/2900 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T58   2400/2900 @ 50Hz (0.01s/0.01s) Sweeping Any T24 T12
T59   2500/3000 @ 2Hz (0.25s/0.25s) Sweeping Any T24 T12
T60   2500/3000 @ 7.7Hz (0.65s/0.65s) Sweeping Any T24 T12
T61   800Hz Motor Siren Any T24 T12
T62   1200Hz Motor Siren Any T24 T12
T63   2400Hz Motor Siren Any T24 T12
T64   Simulated Bell Any T21 T12
Country specific or custom tone configurations and alarm frequencies are available upon request.