ab105strdc24r-r-loa-va-den-bao-ab105str-alarm-sounder-xenon-strobe.png

 

Description

The beacon and sounder can be operated from the same power source or controlled individually.

The AB105STR Xenon beacon component features an automatically synchronised flash rate of 1Hz (60 flashes per minute) as standard. The DC voltage versions also have user selectable 1.5Hz (90 flashes per minute) and double-strike flash rates. The double strike flash rate can be remotely activated via a third wire (as can alternative alarm tones on the horn sounder) enabling a audible and visual communication of a two stage alarm condition.

Specification

Sounder:  
Maximum output: 112dB(A)1m [103dB(A)10ft/3m]
Nominal output: 105dB(A)1m +/-3dB Tone 2 {96dB(A)10ft/3m]
No. of tones: 32 (UKOOA / PFEER compliant)
No. of stages: Alarm horn:3, Xenon Beacon (DC only):2
Double strike pattern can be remotely switched
Volume control: Max. 105dB(A); Min. 96dB(A) – Tone 2
Effective range: 60m/197ft @ 1KHz
Stage switching: Negative (Reverse polarity switching on DC units)
Beacon:  
Energy: 5 Joules (5Ws)
Flash rate: 1Hz (60 fpm)
DC units: Optionally 1.5Hz & double strike
Synchronisation: 1Hz flash rate automatically synchronised
Peak Candela: 500,000 cd – calculated from energy (J)
Eff. Intensity cd: 250 cd – calculated from energy (J)
Peak Candela: 49,788 cd* – measured ref. to I.E.S.
Eff. Intensity cd: 125 cd* – measured ref. to I.E.S.
Tube life: 70% emissions after 8 million flashes
General:  
Voltages DC: 24V dc (10-30V dc); 48V dc (35-60V dc)
[DC units can use 24V ac for single stage applications.]
Voltages AC: 24V ac; 115V ac; 230V ac
Ingress protection: IP65
Enclosure material: High impact UL94 V0 & 5VA FR ABS
Lens material: UV stable PC UL94 V0 FR
Bayonet lens fixing , Anti-tamper locking screw.
Cable entries: 2 x M20 clearance gland entries in side & back
Terminals: 0.5 to 1.5mm² cables.
Operating temp: -25 to +55°C [-13° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20° [68°F]
Weight: DC: 1.00kg/2.2Ibs AC:1.25kg/2.75Ibs

Candela measurements representative of performance with clear lens at optimum voltage.
SPL data +/-3dB(A). Measured at optimum voltage.

 

Part Codes

Version: Part code:
12V dc AB105STRDC12[x]/[y]
24V dc AB105STRDC24[x]/[y]
48V dc AB105STRDC48[x]/[y]
24V ac AB105STRAC24[x]/[y]
115V ac AB105STRAC115[x]/[y]
230V ac AB105STRAC230[x]/[y]
[x] = Enclosure colour: G: Grey R: Red
[y] = Lens colour: A: Amber B: Blue C: Clear
G: Green R: Red Y: Yellow
Suffix part number with ‘-P’ for stage programmable, 4 stage, 45 tone version.